Commit dd816b45 authored by Guenter Roeck's avatar Guenter Roeck Committed by Jiri Slaby
Browse files

hwmon: (smsc47m192) Fix temperature limit and vrm write operations



commit 043572d5 upstream.

Temperature limit clamps are applied after converting the temperature
from milli-degrees C to degrees C, so either the clamp limit needs
to be specified in degrees C, not milli-degrees C, or clamping must
happen before converting to degrees C. Use the latter method to avoid
overflows.

vrm is an u8, so the written value needs to be limited to [0, 255].

Cc: Axel Lin <axel.lin@ingics.com>
Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
Reviewed-by: default avatarJean Delvare <jdelvare@suse.de>
Signed-off-by: default avatarJiri Slaby <jslaby@suse.cz>