Skip to content
Commit d6423bd0 authored by Steffen Dirkwinkel's avatar Steffen Dirkwinkel Committed by Andy Shevchenko
Browse files

platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table



There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.

Fixes: 648e9218 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: default avatarSteffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: default avatarAndy Shevchenko <andriy.shevchenko@linux.intel.com>
parent 3d0818f5