Commit b8e6f136 authored by James Smart's avatar James Smart Committed by Martin K. Petersen
Browse files

scsi: lpfc: Fix incorrect logical link speed on trunks when links down



Invalid logical speed is displayed for trunk enabled ports when all ports
are down. Also noted that link speed is incorrectly reported for the units
when links are up.

Current code is returning the logical link speed from the last event from
the adapter. In cases where the last link went down, the link speed in the
event was not valid - meaning that although the links where down the field
had a bogus value.

Rework the event handling to qualify the trunk link state before using the
event speed data.

Also correct units on other areas where the logical link speed was taken
from a link event.

Signed-off-by: default avatarDick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: default avatarJames Smart <jsmart2021@gmail.com>
Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>