unix_diag: fix incorrect sign extension in unix_lookup_by_ino
The value passed by unix_diag_get_exact to unix_lookup_by_ino has type __u32, but unix_lookup_by_ino's argument ino has type int, which is not a problem yet. However, when ino is compared with sock_i_ino return value of type unsigned long, ino is sign extended to signed long, and this results to incorrect comparison on 64-bit architectures for inode numbers greater than INT_MAX. This bug was found by strace test suite. Fixes: 5d3cae8b ("unix_diag: Dumping exact socket core") Signed-off-by: Dmitry V. Levin <ldv@altlinux.org> Acked-by: Cong Wang <xiyou.wangcong@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>