mmc: sdhci-of-esdhc: add erratum A008171 support
In tuning mode of operation, when TBCTL[TB_EN] is set, eSDHC may report one of the following errors : 1)Tuning error while running tuning operation where SYSCTL2[SAMPCLKSEL] will not get set even when SYSCTL2[EXTN] is reset. OR 2)Data transaction error (e.g. IRQSTAT[DCE], IRQSTAT[DEBE]) during data transaction errors. This issue occurs when the data window sampled within eSDHC is in full cycle. So, in that case, eSDHC is not able to find out the start and end points of the data window and sets the sampling pointer at default location (which is middle of the internal SD clock). If this sampling point coincides with the data eye boundary, then it can result in the above mentioned errors. Impact: Tuning mode of operation for SDR50, SDR104 or HS200 speed modes may not work properly Workaround: In case eSDHC reports tuning error or data errors in tuning mode of operation, by add the erratum A008171 support to fix the issue. Signed-off-by: Yinbo Zhu <yinbo.zhu@nxp.com> Acked-by: Adrian Hunter <adrian.hunter@intel.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>