md: fix 'degraded' calculation when starting a reshape.
This code was written long ago when it was not possible to reshape a degraded array. Now it is so the current level of degraded-ness needs to be taken in to account. Also newly addded devices should only reduce degradedness if they are deemed to be in-sync. In particular, if you convert a RAID5 to a RAID6, and increase the number of devices at the same time, then the 5->6 conversion will make the array degraded so the current code will produce a wrong value for 'degraded' - "-1" to be precise. If the reshape runs to completion end_reshape will calculate a correct new value for 'degraded', but if a device fails during the reshape an incorrect decision might be made based on the incorrect value of "degraded". This patch is suitable for 2.6.32-stable and if they are still open, 2.6.31-stable and 2.6.30-stable as well. Cc: stable@kernel.org Reported-by: Michael Evans <mjevans1983@gmail.com> Signed-off-by: NeilBrown <neilb@suse.de>