Commit 88c6511a authored by Nicholas Piggin's avatar Nicholas Piggin Committed by Michael Ellerman
Browse files

powerpc/64s: Clean up machine check recovery flushing



Use the flush function introduced with the POWER9 machine check handler
for POWER7 and 8, rather than open coding it multiple times in callers.

There is a specific ERAT flush type introduced for POWER9, but the
POWER7-8 ERAT errors continue to do SLB flushing (which also flushes
ERAT), so as not to introduce functional changes with this cleanup
patch.

Signed-off-by: default avatarNicholas Piggin <npiggin@gmail.com>
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
parent fc84427b