Skip to content
Unverified Commit 77ad0f2e authored by Viresh Kumar's avatar Viresh Kumar Committed by Maxime Ripard
Browse files

ARM: dts: sun8i-h3: Add missing cooling device properties for CPUs



The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Fix other missing properties (clocks, clock-names) as well to make it all
work.

Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarMaxime Ripard <maxime.ripard@bootlin.com>