net/mlx5: Enable host PF HCA after eswitch is initialized
Currently ECPF enables external host PF too early in the initialization sequence for Ethernet links when ECPF is eswitch manager. Due to this, when external host PF driver is loaded, host PF's HCA CAP has inner_ip_version supported by NIC RX flow table. This capability is later updated by firmware after ECPF driver enables ENCAP/DECAP as eswitch manager. This results into a timing race condition, where CREATE_TIR command fails with a below syndrome on host PF. mlx5_cmd_check:775:(pid 510): CREATE_TIR(0x900) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x562b00) Hence, enable the external host PF after necessary eswitch and per vport initialization is completed. Continue to enable host PF when eswitch manager capability is off for a ECPF. Signed-off-by: Parav Pandit <parav@nvidia.com> Reviewed-by: Bodong Wang <bodong@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>