serial: pl011: Drop redundant DTR/RTS preservation on close/open
Commit d8d8ffa4 ("amba-pl011: do not disable RTS during shutdown") amended the PL011 serial driver to leave DTR/RTS polarity untouched on tty close. That change made sense. But the commit also added code to save DTR/RTS state to an internal variable on tty close and restore it on tty open. That part of the commit makes less sense: The driver has no ->pm() callback, so the uart remains powered after tty close and automatically preserves register state, including DTR/RTS. Saving and restoring registers isn't the job of the ->startup() and ->shutdown() callbacks anyway. Rather, it should happen in ->pm(). Additionally, after pl011_startup() restores the state, the serial core overrides it in uart_port_dtr_rts() if a baud rate has been set: tty_port_open() uart_port_activate() uart_startup() uart_port_startup() pl011_startup() # restores DTR/RTS from uap->old_cr tty_port_block_til_ready() tty_port_raise_dtr_rts # if (C_BAUD(tty)) uart_dtr_rts() uart_port_dtr_rts() # raises DTR/RTS The serial core also overrides DTR/RTS on tty close in uart_shutdown() if C_HUPCL(tty) is set. So a user-defined DTR/RTS polarity won't survive a close/open cycle anyway, unless the user has set the baud rate to zero and disabled hupcl on the tty. Bottom line is, the code to save and restore DTR/RTS has no effect. Remove it. Cc: Linus Walleij <linus.walleij@linaro.org> Cc: Russell King <rmk+kernel@armlinux.org.uk> Signed-off-by:Lukas Wunner <lukas@wunner.de> Link: https://lore.kernel.org/r/e22089ab49e6e78822c50c8c4db46bf3ee885623.1641129328.git.lukas@wunner.de Signed-off-by:
Greg Kroah-Hartman <gregkh@linuxfoundation.org>