Skip to content
  1. Nov 15, 2019
    • Vladimir Oltean's avatar
      net: dsa: sja1105: Implement state machine for TAS with PTP clock source · 86db36a3
      Vladimir Oltean authored
      
      
      Tested using the following bash script and the tc from iproute2-next:
      
      	#!/bin/bash
      
      	set -e -u -o pipefail
      
      	NSEC_PER_SEC="1000000000"
      
      	gatemask() {
      		local tc_list="$1"
      		local mask=0
      
      		for tc in ${tc_list}; do
      			mask=$((${mask} | (1 << ${tc})))
      		done
      
      		printf "%02x" ${mask}
      	}
      
      	if ! systemctl is-active --quiet ptp4l; then
      		echo "Please start the ptp4l service"
      		exit
      	fi
      
      	now=$(phc_ctl /dev/ptp1 get | gawk '/clock time is/ { print $5; }')
      	# Phase-align the base time to the start of the next second.
      	sec=$(echo "${now}" | gawk -F. '{ print $1; }')
      	base_time="$(((${sec} + 1) * ${NSEC_PER_SEC}))"
      
      	tc qdisc add dev swp5 parent root handle 100 taprio \
      		num_tc 8 \
      		map 0 1 2 3 5 6 7 \
      		queues 1@0 1@1 1@2 1@3 1@4 1@5 1@6 1@7 \
      		base-time ${base_time} \
      		sched-entry S $(gatemask 7) 100000 \
      		sched-entry S $(gatemask "0 1 2 3 4 5 6") 400000 \
      		clockid CLOCK_TAI flags 2
      
      The "state machine" is a workqueue invoked after each manipulation
      command on the PTP clock (reset, adjust time, set time, adjust
      frequency) which checks over the state of the time-aware scheduler.
      So it is not monitored periodically, only in reaction to a PTP command
      typically triggered from a userspace daemon (linuxptp). Otherwise there
      is no reason for things to go wrong.
      
      Now that the timecounter/cyclecounter has been replaced with hardware
      operations on the PTP clock, the TAS Kconfig now depends upon PTP and
      the standalone clocksource operating mode has been removed.
      
      Signed-off-by: default avatarVladimir Oltean <olteanv@gmail.com>
      Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
      86db36a3
    • Vladimir Oltean's avatar
      net: dsa: sja1105: Make the PTP command read-write · 41603d78
      Vladimir Oltean authored
      
      
      The PTPSTRTSCH and PTPSTOPSCH bits are actually readable and indicate
      whether the time-aware scheduler is running or not. We will be using
      that for monitoring the scheduler in the next patch, so refactor the PTP
      command API in order to allow that.
      
      Signed-off-by: default avatarVladimir Oltean <olteanv@gmail.com>
      Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
      41603d78
  2. Nov 14, 2019
  3. Nov 13, 2019