iio: adc: xilinx-xadc: Correct temperature offset/scale for UltraScale
The driver was previously using offset and scale values for the temperature sensor readings which were only valid for 7-series devices. Add per-device-type values for offset and scale and set them appropriately for each device type. Note that the values used for the UltraScale family are for UltraScale+ (i.e. the SYSMONE4 primitive) using the internal reference, as that seems to be the most common configuration and the device tree values Xilinx's device tree generator produces don't seem to give us anything to tell us which configuration is used. However, the differences within the UltraScale family seem fairly minor and it's closer than using the 7-series values instead in any case. Fixes: c2b7720a ("iio: xilinx-xadc: Add basic support for Ultrascale System Monitor") Signed-off-by: Robert Hancock <robert.hancock@calian.com> Acked-by: O'Griofa, Conall <conall.ogriofa@amd.com> Tested-by: O'Griofa, Conall <conall.ogriofa@amd.com> Link: https://lore.kernel.org/r/20230915001019.2862964-3-robert.hancock@calian.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>