Input: edt-ft5x06 - work around first register access error
The EP0700MLP1 returns bogus data on the first register read access (reading the threshold parameter from register 0x00): edt_ft5x06 2-0038: crc error: 0xfc expected, got 0x40 It ignores writes until then. This patch adds a dummy read after which the number of sensors and parameter read/writes work correctly. Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de> Signed-off-by: Marco Felsch <m.felsch@pengutronix.de> Tested-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>