power: supply: ab8500: Standardize maintenance charging



Maintenance charging is the phase of keeping up the charge
after the battery has charged fully using CC/CV charging.

This can be done in many successive phases and is usually
done with a slightly lower constant voltage than CV, and
a slightly lower allowed current.

Add an array of maintenance charging points each with a
current, voltage and safety timer, and add helper functions
to use these. Migrate the AB8500 code over.

This is used in several Samsung products using the AB8500
and these batteries and their complete parameters will
be added later as full examples, but the default battery
in the AB8500 code serves as a reasonable example so far.

Reviewed-by: default avatarMatti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: default avatarLinus Walleij <linus.walleij@linaro.org>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>