Commit d157fca7 authored by Daniel Mack's avatar Daniel Mack Committed by Greg Kroah-Hartman
Browse files

serial: tty: uartlite: fix console setup



Remove the hack to assign the global console_port variable at probe time.
This assumption that cons->index is -1 is wrong for systems that specify
'console=' in the cmdline (or 'stdout-path' in dts). Hence, on such system
the actual console assignment is ignored, and the first UART that happens
to be probed is used as console instead.

Move the logic to console_setup() and map the console to the correct port
through the array of available ports instead.

Signed-off-by: default avatarDaniel Mack <daniel@zonque.org>
Link: https://lore.kernel.org/r/20210528133321.1859346-1-daniel@zonque.org


Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 236b26f1