mmc: meson-gx: improve initial configuration
Config values which are not changed during runtime we can set in the probe function already. The block size setting is overwritten later in meson_mmc_start_cmd anyway if needed, so it doesn't harm if we remove this setting in meson_mmc_set_ios. In addition write config register only if configuration changed. Don't change the location of clock initialization as in an earlier version of the patch, this change causes a hang. This issue was reported and fix suggested by: Helmut Klein <hgkr.klein@gmail.com> Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com> Acked-by: Kevin Hilman <khilman@baylibre.com> Tested-by: Kevin Hilman <khilman@baylibre.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
Please register or sign in to comment