Commit b14d72ac authored by Fabrice Gasnier's avatar Fabrice Gasnier Committed by Jonathan Cameron
Browse files

counter: stm32-timer-cnt: fix ceiling miss-alignment with reload register



Ceiling value may be miss-aligned with what's actually configured into the
ARR register. This is seen after probe as currently the ARR value is zero,
whereas ceiling value is set to the maximum. So:
- reading ceiling reports zero
- in case the counter gets enabled without any prior configuration,
  it won't count.
- in case the function gets set by the user 1st, (priv->ceiling) is used.

Fix it by getting rid of the cached "priv->ceiling" variable. Rather use
the ARR register value directly by using regmap read or write when needed.
There should be no drawback on performance as priv->ceiling isn't used in
performance critical path.
There's also no point in writing ARR while setting function (sms), so
it can be safely removed.

Fixes: ad29937e ("counter: Add STM32 Timer quadrature encoder")
Suggested-by: default avatarWilliam Breathitt Gray <vilhelm.gray@gmail.com>
Signed-off-by: default avatarFabrice Gasnier <fabrice.gasnier@foss.st.com>
Acked-by: default avatarWilliam Breathitt Gray <vilhelm.gray@gmail.com>
Cc: <Stable@vger.kernel.org>
Link: https://lore.kernel.org/r/1614793789-10346-1-git-send-email-fabrice.gasnier@foss.st.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent e4c3e133
0% or .