Commit a5436af5 authored by Brandon Wyman's avatar Brandon Wyman Committed by Guenter Roeck
Browse files

hwmon: (pmbus) Add Vin unit off handling



If there is an input undervoltage fault, reported in STATUS_INPUT
command response, there is quite likely a "Unit Off For Insufficient
Input Voltage" condition as well.

Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit
attributes to include both bits in the mask for clearing faults.

If an input undervoltage fault occurs, causing a unit off for
insufficient input voltage, but the unit is off bit is not cleared, the
STATUS_WORD will not be updated to clear the input fault condition.
Including the unit is off bit (bit 3) allows for the input fault
condition to completely clear.

Signed-off-by: default avatarBrandon Wyman <bjwyman@gmail.com>
Link: https://lore.kernel.org/r/20220317232123.2103592-1-bjwyman@gmail.com


Fixes: b4ce237b ("hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers")
[groeck: Dropped unnecessary ()]
Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>