Skip to content
Commit 9d901e35 authored by Olivier Moysan's avatar Olivier Moysan Committed by Jonathan Cameron
Browse files

iio: adc: stm32-adc: smart calibration support



Add smart calibration support for STM32MP1.
- STM32MP15x: both linear & offset calibration are supported
- STM32MP13x: Only offset calibration is supported

Linear calibration:
Linear calibration is SoC dependent and does not change over time
so it can be done only once.
Linear calibration may have already been done in u-boot.
Skip calibration execution if calibration data are already available.
Save calibration factors in private data and restore them from private
data on next ADC start.

Offset calibration:
This calibration may vary over time, depending on temperature or voltage.
Run offset single-ended and differential calibration on each ADC start,
as it is not time consuming. This calibration do not need to be saved.
So, remove calfact_s and calfact_d value and bitfields that are no
longer used.

Signed-off-by: default avatarOlivier Moysan <olivier.moysan@foss.st.com>
Reviewed-by: default avatarFabrice Gasnier <fabrice.gasnier@foss.st.com>
Link: https://lore.kernel.org/r/20221115103124.70074-2-olivier.moysan@foss.st.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>