Skip to content
Commit 9c56679d authored by Dmitry Osipenko's avatar Dmitry Osipenko Committed by Krzysztof Kozlowski
Browse files

memory: tegra124-emc: Continue probing if timings are missing in device-tree



EMC driver will become mandatory after turning it into interconnect
provider because interconnect users, like display controller driver, will
fail to probe using newer device-trees that have interconnect properties.
Thus make EMC driver to probe even if timings are missing in device-tree.

Tested-by: default avatarNicolas Chauvet <kwizart@gmail.com>
Signed-off-by: default avatarDmitry Osipenko <digetx@gmail.com>
Link: https://lore.kernel.org/r/20201228154920.18846-3-digetx@gmail.com


Signed-off-by: default avatarKrzysztof Kozlowski <krzk@kernel.org>
parent 281462e5