x86, UV: Remove BAU check for stay-busy
Remove a faulty assumption that a long running BAU request has encountered a hardware problem and will never finish. Numalink congestion can make a request appear to have encountered such a problem, but it is not safe to cancel the request. If such a cancel is done but a reply is later received we can miss a TLB shootdown. We depend upon the max_bau_concurrent 'throttle' to prevent the stay-busy case from happening. Signed-off-by: Cliff Wickman <cpw@sgi.com> Cc: gregkh@suse.de LKML-Reference: <E1OJvNy-0004ad-BV@eag09.americas.sgi.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>