Commit 5fc336c6 authored by Ian Abbott's avatar Ian Abbott Committed by Greg Kroah-Hartman
Browse files

staging: comedi: dt2814: Call dt2814_ai_clear() during initialization



The Comedi "attach" handler `dt2814_attach()` writes to the Control
register to turn off the timer enable 'ENB' bit, which triggers a
conversion.  It then sleeps awhile and checks the Status register,
returning an error if the ERR bit is set.  However, the ERR bit could
have been set due to the conversion being triggered while the A/D
converter was busy (unlikely) or due to the conversion being triggered
before some previous sample had been read from the A/D Data register.

Replace the existing code with a call to `dt2814_ai_clear()` which waits
for any conversion to finish and then clears any unread data or error
condition.  A non-zero return value from `dt2814_ai_clear()` indicates a
time-out while waiting for the A/D converter to become non-busy.  Return
an error in that case.

Signed-off-by: default avatarIan Abbott <abbotti@mev.co.uk>
Link: https://lore.kernel.org/r/20210301165757.243065-4-abbotti@mev.co.uk


Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 46ffba06