Skip to content
Commit 5e00e326 authored by Karol Herbst's avatar Karol Herbst Committed by Ben Skeggs
Browse files

drm/nouveau/volt: Don't require perfect fit



If we calculate the voltage in the table right, we get all kinds of values,
which never fit the hardware steps, so we use the closest higher value the
hardware can do.

v3: Simplify the implementation.
v5: Initialize best_err with volt->max_uv.

Signed-off-by: default avatarKarol Herbst <karolherbst@gmail.com>
Reviewed-by: default avatarMartin Peres <martin.peres@free.fr>
Signed-off-by: default avatarBen Skeggs <bskeggs@redhat.com>
parent 4b9ce6e7