net: phy: marvell-88q2xxx: add cable test support



Add cable test support for Marvell 88Q222x devices. Reported distance
granularity is 1m.

1m cable, open:
  Cable test started for device eth0.
  Cable test completed for device eth0.
  Pair A code Open Circuit
  Pair A, fault length: 1.00m

1m cable, shorted:
  Cable test started for device eth0.
  Cable test completed for device eth0.
  Pair A code Short within Pair
  Pair A, fault length: 1.00m

6m cable, open:
  Cable test started for device eth0.
  Cable test completed for device eth0.
  Pair A code Open Circuit
  Pair A, fault length: 6.00m

6m cable, shorted:
  Cable test started for device eth0.
  Cable test completed for device eth0.
  Pair A code Short within Pair
  Pair A, fault length: 6.00m

Signed-off-by: default avatarDimitri Fedrau <dima.fedrau@gmail.com>
Reviewed-by: default avatarAndrew Lunn <andrew@lunn.ch>
Link: https://lore.kernel.org/r/20240218075753.18067-10-dima.fedrau@gmail.com


Signed-off-by: default avatarJakub Kicinski <kuba@kernel.org>
parent a557a92e