net: ethernet: ti: cpsw: adjust cpsw fifos depth for fullduplex flow control
When users set flow control using ethtool the bits are set properly in the CPGMAC_SL MACCONTROL register, but the FIFO depth in the respective Port n Maximum FIFO Blocks (Pn_MAX_BLKS) registers remains set to the minimum size reset value. When receive flow control is enabled on a port, the port's associated FIFO block allocation must be adjusted. The port RX allocation must increase to accommodate the flow control runout. The TRM recommends numbers of 5 or 6. Hence, apply required Port FIFO configuration to Pn_MAX_BLKS.Pn_TX_MAX_BLKS=0xF and Pn_MAX_BLKS.Pn_RX_MAX_BLKS=0x5 during interface initialization. Cc: Schuyler Patton <spatton@ti.com> Signed-off-by: Grygorii Strashko <grygorii.strashko@ti.com> Signed-off-by: David S. Miller <davem@davemloft.net>