Skip to content
Commit 38d6211e authored by Nadav Haklai's avatar Nadav Haklai Committed by Mark Brown
Browse files

spi: orion: On a38x, implement "50MHZ SPI AC timing" Erratum No. FE-9144572



Description:
On Armada 38x, the device SPI interface supports frequencies of up to
50 MHz. However, due to this erratum, when the device core clock is
250 MHz and the SPI interfaces is configured for 50MHz SPI clock and
CPOL=CPHA=1, there might occur data corruption on reads from the SPI
device.

Workaround:
Work in one of the following configurations:
1. Set CPOL=CPHA=0 in "SPI Interface Configuration Register".
2. Set TMISO_SAMPLE value to 0x2 in "SPI Timing Parameters 1 Register"
before setting the interface.

[gregory.clement@free-electrons.com}: port to v4.2-rc, use
is_errata_50mhz_ac instead of using a new ARMADA_380_SPI spi type.

Signed-off-by: default avatarNadav Haklai <nadavh@marvell.com>
Signed-off-by: default avatarGregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: default avatarMark Brown <broonie@kernel.org>
Cc: stable@vger.kernel.org
parent bc0195aa