Skip to content
Commit 36eee232 authored by Pierre-Louis Bossart's avatar Pierre-Louis Bossart Committed by Vinod Koul
Browse files

soundwire: cadence_master: always set CMD_ACCEPT



The Cadence IP can be configured in two different ways to deal with
CMD_IGNORED replies to broadcast commands. The CMD_ACCEPT bitfield
controls whether the command is discarded or if the IP proceeds with
the change (typically a bank switch or clock stop command).

The existing code seems to be inconsistent:
a) For some historical reason, we set this CMD_ACCEPT bitfield during
the initialization, but we don't during a resume from a clock-stoppped
state.
b) In addition, the loop used in the clock-stop sequence is quite
racy, it's possible that a device has lost sync but it's still tagged
as ATTACHED.
c) If somehow a Device loses sync and is unable to ack a broadcast
command, we do not have an error handling mechanism anyways. The IP
should go ahead and let the Device regain sync at a later time.

Make sure the CMD_ACCEPT bit is always set.

Signed-off-by: default avatarPierre-Louis Bossart <pierre-louis.bossart@linux.intel.com>
Reviewed-by: default avatarGuennadi Liakhovetski <guennadi.liakhovetski@linux.intel.com>
Reviewed-by: default avatarRander Wang <rander.wang@intel.com>
Signed-off-by: default avatarBard Liao <yung-chuan.liao@linux.intel.com>
Link: https://lore.kernel.org/r/20210511025247.25339-1-yung-chuan.liao@linux.intel.com


Signed-off-by: default avatarVinod Koul <vkoul@kernel.org>
parent 54a6ca4f
Loading
Loading
Loading
Loading
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Please register or to comment