hwmon: (pmbus) Add list_voltage to pmbus ops
When checking if a regulator supports a voltage range, the regulator needs to have a list_voltage callback set to the regulator_ops or else -EINVAL will be returned. This support does not exist for the pmbus regulators, so this patch adds pmbus_regulator_list_voltage to the pmbus_regulator_ops. Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com> Link: https://lore.kernel.org/r/20220614093856.3470672-3-marten.lindahl@axis.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>