Skip to content
Commit 18807ddb authored by Yazen Ghannam's avatar Yazen Ghannam Committed by Thomas Gleixner
Browse files

x86/mce/AMD: Reset Threshold Limit after logging error



The error count field in MCA_MISC does not get reset by hardware when the
threshold has been reached. Software is expected to reset it. Currently,
the threshold limit only gets reset during init or when a user writes to
sysfs.

If the user is not monitoring threshold interrupts and resetting
the limit then the user will only see 1 interrupt when the limit is first
hit. So if, for example, the limit is set to 10 then only 1 interrupt will
be recorded after 10 errors even if 100 errors have occurred. The user may
then assume that only 10 errors have occurred.

Signed-off-by: default avatarYazen Ghannam <Yazen.Ghannam@amd.com>
Cc: Aravind Gopalakrishnan <aravindksg.lkml@gmail.com>
Cc: linux-edac <linux-edac@vger.kernel.org>
Cc: x86-ml <x86@kernel.org>
Link: http://lkml.kernel.org/r/1479244433-69267-1-git-send-email-Yazen.Ghannam@amd.com
Signed-off-by: default avatarBorislav Petkov <bp@suse.de>
Signed-off-by: default avatarThomas Gleixner <tglx@linutronix.de>
parent 859af13a
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment