net: mvpp2: fix the synchronization module bypass macro name



The macro defining the bit to toggle to bypass or not the
synchronization module is wrongly named. Writing 1 will disable bypass.
This patch s/MVPP22_CTRL4_SYNC_BYPASS/MVPP22_CTRL4_SYNC_BYPASS_DIS/.

Signed-off-by: default avatarAntoine Tenart <antoine.tenart@free-electrons.com>
Tested-by: default avatarMarcin Wojtas <mw@semihalf.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>