Skip to content
Commit 0c072385 authored by Babu Moger's avatar Babu Moger Committed by Guenter Roeck
Browse files

hwmon: (k10temp) Check range scale when CUR_TEMP register is read-write



Spec says, when CUR_TEMP_TJ_SEL == 3 and CUR_TEMP_RANGE_SEL == 0,
it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. The
CUR_TEMP register is read-write when CUR_TEMP_TJ_SEL == 3 (bit 17-16).

Add the check to detect it.

Sensors command's output before the patch.
$sensors
 k10temp-pci-00c3
 Adapter: PCI adapter
 Tctl:         +76.6°C <- Wrong value
 Tccd1:        +26.5°C
 Tccd2:        +27.5°C
 Tccd3:        +27.2°C
 Tccd4:        +27.5°C
 Tccd5:        +26.0°C
 Tccd6:        +26.2°C
 Tccd7:        +25.0°C
 Tccd8:        +26.5°C

Sensors command's output after the patch.
$sensors
 k10temp-pci-00c3
 Adapter: PCI adapter
 Tctl:         +28.8°C <- corrected value
 Tccd1:        +27.5°C
 Tccd2:        +28.5°C
 Tccd3:        +28.5°C
 Tccd4:        +28.5°C
 Tccd5:        +27.0°C
 Tccd6:        +27.5°C
 Tccd7:        +27.0°C
 Tccd8:        +27.5°C

Signed-off-by: default avatarBabu Moger <babu.moger@amd.com>
Fixes: 1b597889 ("hwmon: (k10temp) Add temperature offset for Ryzen 2700X")
Link: https://lore.kernel.org/r/20230413213958.847634-1-babu.moger@amd.com


Cc: stable@vger.kernel.org
Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>