Skip to content
Commit 063578dc authored by Lars-Peter Clausen's avatar Lars-Peter Clausen Committed by Stephen Boyd
Browse files

clk: axi-clkgen: Correctly handle nocount bit in recalc_rate()



If the nocount bit is set the divider is bypassed and the settings for the
divider count should be ignored and a divider value of 1 should be assumed.
Handle this correctly in the driver recalc_rate() callback.

While the driver sets up the part so that the read back dividers values
yield the correct result the power-on reset settings of the part might not
reflect this and hence calling e.g. clk_get_rate() without prior calls to
clk_set_rate() will yield the wrong result.

Signed-off-by: default avatarLars-Peter Clausen <lars@metafoo.de>
Signed-off-by: default avatarStephen Boyd <sboyd@codeaurora.org>
parent 4fbd8d19