Skip to content
Commit e1d91485 authored by Mario Limonciello's avatar Mario Limonciello Committed by Rafael J. Wysocki
Browse files

ACPICA: Drop port I/O validation for some regions

Microsoft introduced support in Windows XP for blocking port I/O
to various regions.  For Windows compatibility ACPICA has adopted
the same protections and will disallow writes to those
(presumably) the same regions.

On some systems the AML included with the firmware will issue 4 byte
long writes to 0x80.  These writes aren't making it over because of this
blockage. The first 4 byte write attempt is rejected, and then
subsequently 1 byte at a time each offset is tried. The first at 0x80
works, but then the next 3 bytes are rejected.

This manifests in bizarre failures for devices that expected the AML to
write all 4 bytes.  Trying the same AML on Windows 10 or 11 doesn't hit
this failure and all 4 bytes are written.

Either some of these regions were wrong or some point after Windows XP
some of these regions blocks have been lifted.

In the last 15 years there doesn't seem to be any reports popping up of
this error in the Windows event viewer anymore.  There is no documentation
at Microsoft's developer site indicating that Windows ACPI interpreter
blocks these regions. Between the lack of documentation and the fact that
the writes actually do work in Windows 10 and 11, it's quite likely
Windows doesn't actually enforce this anymore.

So to help the issue, only enforce Windows XP specific entries if the
latest _OSI supported is Windows XP. Continue to enforce the
ALWAYS_ILLEGAL entries.

Link: https://github.com/acpica/acpica/pull/817
Fixes: 7f071903

 ("ACPICA: New: I/O port protection")
Signed-off-by: default avatarMario Limonciello <mario.limonciello@amd.com>
Signed-off-by: default avatarRafael J. Wysocki <rafael.j.wysocki@intel.com>
parent 1b929c02
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment