nvme: hwmon: add quirk to avoid changing temperature threshold



This adds a new quirk NVME_QUIRK_NO_TEMP_THRESH_CHANGE to avoid changing
the value of the temperature threshold feature for specific devices that
show undesirable behavior.

Guenter reported:

"On my Intel NVME drive (SSDPEKKW512G7), writing any minimum limit on the
Composite temperature sensor results in a temperature warning, and that
warning is sticky until I reset the controller.

It doesn't seem to matter which temperature I write; writing -273000 has
the same result."

The Intel NVMe has the latest firmware version installed, so this isn't
a problem that was ever fixed.

Reported-by: default avatarGuenter Roeck <linux@roeck-us.net>
Cc: Keith Busch <kbusch@kernel.org>
Cc: Jens Axboe <axboe@fb.com>
Cc: Christoph Hellwig <hch@lst.de>
Cc: Sagi Grimberg <sagi@grimberg.me>
Cc: Jean Delvare <jdelvare@suse.com>
Reviewed-by: default avatarGuenter Roeck <linux@roeck-us.net>
Tested-by: default avatarGuenter Roeck <linux@roeck-us.net>
Signed-off-by: default avatarAkinobu Mita <akinobu.mita@gmail.com>
Signed-off-by: default avatarKeith Busch <kbusch@kernel.org>