ARM: mvebu: use clocks property for serial ports
Back when the Armada 370 and Armada XP initial support was introduced, the only way to pass the clock frequency to the of_serial driver was through a clock-frequency Device Tree property. Thanks to 0bbeb3c3 ('of serial port driver - add clk_get_rate() support'), it is possible to use the standard 'clocks' DT property to reference the clock used for a particular UART controller. This clock is then used by the of_serial driver to retrieve the clock rate. This commit modifies the SoC-level Device Tree files of Armada 370, Armada XP, Armada 375 and Armada 38x to use this possibility. Since there is no gatable clock for the UART controllers, we simply reference the TCLK, which is the main SoC clock for the peripherals. Signed-off-by: Thomas Petazzoni <thomas.petazzoni@free-electrons.com> Acked-by: Gregory CLEMENT <gregory.clement@free-electrons.com> Link: https://lkml.kernel.org/r/1397806908-7550-4-git-send-email-thomas.petazzoni@free-electrons.com Signed-off-by: Jason Cooper <jason@lakedaemon.net>