Skip to content
Unverified Commit cbae1a35 authored by Andreas Pape's avatar Andreas Pape Committed by Mark Brown
Browse files

ASoC: rcar: adg: correct TIMSEL setting for SSI9



Timing select registers for SRC and CMD are by default
referring to the corresponding SSI word select.
The calculation rule from HW spec skips SSI8, which has
no clock connection.

>From section 43.2.18 CMD Output Timing Select Register (CMDOUT_TIMSEL),
of R-Car Series, 3rd Generation Hardware User’s Manual Rev.2.20:

CMD0_OUT_DIVCLK_	Output Timing
SEL [4:0]		Signal Select
B'0 0110: 		ssi_ws0
B'0 0111: 		ssi_ws1
B'0 1000: 		ssi_ws2
B'0 1001: 		ssi_ws3
B'0 1010: 		ssi_ws4
B'0 1011: 		ssi_ws5
B'0 1100: 		ssi_ws6
B'0 1101: 		ssi_ws7
	<GAP>
B'0 1110: 		ssi_ws9
B'0 1111: 		Setting prohibited

Fix the erroneous prohibited setting of timsel value 1111 (0xf) for SSI9
by using timsel value 1110 (0xe) instead. This is possible because SSI8
is not connected as shown by <GAP> in the table above.

[21.695055] rcar_sound ec500000.sound: b adg[0]-CMDOUT_TIMSEL (32):00000f00/00000f1f

Correct the timsel assignment.

Fixes: 629509c5 ("ASoC: rsnd: add Gen2 SRC and DMAEngine support")
Suggested-by: default avatarKuninori Morimoto <kuninori.morimoto.gx@renesas.com>
Signed-off-by: default avatarAndreas Pape <Andreas.Pape4@bosch.com>
Signed-off-by: default avatarYeswanth Rayapati <yeswanth.rayapati@in.bosch.com>
Tested-by: default avatarYeswanth Rayapati <yeswanth.rayapati@in.bosch.com>
[erosca: massage commit description]
Signed-off-by: default avatarEugeniu Rosca <eugeniu.rosca@bosch.com>
Acked-by: default avatarKuninori Morimoto <kuninori.morimoto.gx@renesas.com>
Link: https://msgid.link/r/20240301085003.3057-1-erosca@de.adit-jv.com


Signed-off-by: default avatarMark Brown <broonie@kernel.org>
parent f8b0127a
Loading
Loading
Loading
Loading
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Please register or to comment