Commit b6d572ae authored by Mika Westerberg's avatar Mika Westerberg
Browse files

thunderbolt: Increase DisplayPort Connection Manager handshake timeout



It turns out that when plugging in VGA cable through USB-C to VGA/DVI
dongle the Connection Manager handshake can take longer time, at least
on Intel Titan Ridge based docks such as Dell WD91TB. This leads to
following error in the dmesg:

  thunderbolt 0000:00:0d.3: 3:10: DP tunnel activation failed, aborting

and the display stays blank (because we failed to establish the tunnel).
For this reason increase the timeout to 3s.

Reported-by: default avatarKoba Ko <koba.ko@canonical.com>
Cc: stable@vger.kernel.org
Acked-By: default avatarYehezkel Bernat <YehezkelShB@gmail.com>
Signed-off-by: default avatarMika Westerberg <mika.westerberg@linux.intel.com>
parent 70c2e03e