timers/nohz: Switch to ONESHOT_STOPPED in the low-res handler when the tick is stopped
[ Upstream commit 62c1256d ] When tick_nohz_stop_tick() stops the tick and high resolution timers are disabled, then the clock event device is not put into ONESHOT_STOPPED mode. This can lead to spurious timer interrupts with some clock event device drivers that don't shut down entirely after firing. Eliminate these by putting the device into ONESHOT_STOPPED mode at points where it is not being reprogrammed. When there are no timers active, then tick_program_event() with KTIME_MAX can be used to stop the device. When there is a timer active, the device can be stopped at the next tick (any new timer added by timers will reprogram the tick). Signed-off-by: Nicholas Piggin <npiggin@gmail.com> Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Link: https://lore.kernel.org/r/20220422141446.915024-1-npiggin@gmail.com Signed-off-by: Joel Fernandes (Google) <joel@joelfernandes.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>