Commit ae1f7b93 authored by Vasileios Amoiridis's avatar Vasileios Amoiridis Committed by Jonathan Cameron
Browse files

iio: chemical: bme680: Fix pressure value output

The IIO standard units are measured in kPa while the driver
is using hPa.

Apart from checking the userspace value itself, it is mentioned also
in the Bosch API [1] that the pressure value is in Pascal.

[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742



Fixes: 1b3bd859 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: default avatarVasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com


Cc: <Stable@vger.kernel.org>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>