pwm: sifive: Ensure the clk is enabled exactly once per running PWM



.apply() assumes the clk to be for a given PWM iff the PWM is enabled.
So make sure this is the case when .probe() completes. And in .remove()
disable the according number of times.

This fixes a clk enable/disable imbalance, if some PWMs are already running
at probe time.

Fixes: 9e37a53e (pwm: sifive: Add a driver for SiFive SoC PWM)
Signed-off-by: default avatarUwe Kleine-König <u.kleine-koenig@pengutronix.de>
Tested-by: default avatarEmil Renner Berthing <emil.renner.berthing@canonical.com>
Signed-off-by: default avatarThierry Reding <thierry.reding@gmail.com>