tty: serial: samsung: fix tx_empty() to return TIOCSER_TEMT
[ Upstream commit 314c2b39 ] The core expects for tx_empty() either TIOCSER_TEMT when the tx is empty or 0 otherwise. s3c24xx_serial_txempty_nofifo() might return 0x4, and at least uart_get_lsr_info() tries to clear exactly TIOCSER_TEMT (BIT(1)). Fix tx_empty() to return TIOCSER_TEMT. Fixes: 1da177e4 ("Linux-2.6.12-rc2") Signed-off-by: Tudor Ambarus <tudor.ambarus@linaro.org> Reviewed-by: Sam Protsenko <semen.protsenko@linaro.org> Link: https://lore.kernel.org/r/20240119104526.1221243-2-tudor.ambarus@linaro.org Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org> Signed-off-by: Sasha Levin <sashal@kernel.org>