Skip to content
Commit 9547d6a4 authored by Dimitri Fedrau's avatar Dimitri Fedrau Committed by Jonathan Cameron
Browse files

iio: humidity: hdc3020: fix hysteresis representation

According to the ABI docs hysteresis values are represented as offsets to
threshold values. Current implementation represents hysteresis values as
absolute values which is wrong. Nevertheless the device stores them as
absolute values and the datasheet refers to them as clear thresholds. Fix
the reading and writing of hysteresis values by including thresholds into
calculations. Hysteresis values that result in threshold clear values
that are out of limits will be truncated.

To check that the threshold clear values are correct, registers are read
out using i2ctransfer and the corresponding temperature and relative
humidity thresholds are calculated using the formulas in the datasheet.

Fixes: 3ad0e7e5

 ("iio: humidity: hdc3020: add threshold events support")
Signed-off-by: default avatarDimitri Fedrau <dima.fedrau@gmail.com>
Reviewed-by: default avatarJavier Carrasco <javier.carrasco.cruz@gmail.com>
Link: https://lore.kernel.org/r/20240605192136.38146-1-dima.fedrau@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent 75183e46