net: ipa: disable HOLB drop when updating timer
The head-of-line blocking timer should only be modified when head-of-line drop is disabled. One of the steps in recovering from a modem crash is to enable dropping of packets with timeout of 0 (immediate). We don't know how the modem configured its endpoints, so before we program the timer, we need to ensure HOL_BLOCK is disabled. Fixes: 84f9bd12 ("soc: qcom: ipa: IPA endpoints") Signed-off-by: Alex Elder <elder@linaro.org> Signed-off-by: David S. Miller <davem@davemloft.net>
Please register or sign in to comment