power: supply: bq27xxx: Ensure power_supply_changed() is called on current sign changes
[ Upstream commit 939a1161 ] On gauges where the current register is signed, there is no charging flag in the flags register. So only checking flags will not result in power_supply_changed() getting called when e.g. a charger is plugged in and the current sign changes from negative (discharging) to positive (charging). This causes userspace's notion of the status to lag until userspace does a poll. And when a power_supply_leds.c LED trigger is used to indicate charging status with a LED, this LED will lag until the capacity percentage changes, which may take many minutes (because the LED trigger only is updated on power_supply_changed() calls). Fix this by calling bq27xxx_battery_current_and_status() on gauges with a signed current register and checking if the status has changed. Fixes: 297a533b ("bq27x00: Cache battery registers") Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Sasha Levin <sashal@kernel.org>