thermal: qoriq: Enable all sensors before registering them
Tmu_get_temp will get called as a part of sensor registration via devm_thermal_zone_of_sensor_register(). To prevent it from retruning bogus data we need to enable sensor monitoring before that. Looking at the datasheet (i.MX8MQ RM) there doesn't seem to be any harm in enabling them all, so, for the sake of simplicity, change the code to do just that. Signed-off-by: Andrey Smirnov <andrew.smirnov@gmail.com> Tested-by: Lucas Stach <l.stach@pengutronix.de> Cc: Chris Healy <cphealy@gmail.com> Cc: Lucas Stach <l.stach@pengutronix.de> Cc: Eduardo Valentin <edubezval@gmail.com> Cc: Daniel Lezcano <daniel.lezcano@linaro.org> Cc: Angus Ainslie (Purism) <angus@akkea.ca> Cc: linux-imx@nxp.com Cc: linux-pm@vger.kernel.org Cc: linux-kernel@vger.kernel.org Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20191210164153.10463-10-andrew.smirnov@gmail.com