serial: max310x: use a separate regmap for each port
[ Upstream commit 6ef281da ] The driver currently does manual register manipulation in multiple places to talk to a specific UART port. In order to talk to a specific UART port over SPI, the bits U1 and U0 of the register address can be set, as explained in the Command byte configuration section of the datasheet. Make this more elegant by creating regmaps for each UART port and setting the read_flag_mask and write_flag_mask accordingly. All communcations regarding global registers are done on UART port 0, so replace the global regmap entirely with the port 0 regmap. Also, remove the 0x1f masks from reg_writeable(), reg_volatile() and reg_precious() methods, since setting the U1 and U0 bits of the register address happens inside the regmap core now. Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Signed-off-by: Cosmin Tanislav <cosmin.tanislav@analog.com> Link: https://lore.kernel.org/r/20220605144659.4169853-3-demonsingur@gmail.com Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org> Stable-dep-of: b35f8dbb ("serial: max310x: prevent infinite while() loop in port startup") Signed-off-by: Sasha Levin <sashal@kernel.org>