pwm: sifive: Simplify clk handling



The clk is necessary for both register access and (enabled) operation of
the PWM. Instead of

	clk_enable()
	update_hw()
	if pwm_got_enabled():
		clk_enable()
	elif pwm_got_disabled():
		clk_disable()
	clk_disable()

which is some cases only calls clk_enable() to immediately afterwards
call clk_disable again, do:

	if (!prev_state.enabled)
		clk_enable()

	# clk enabled exactly once

	update_hw()

	if (!next_state.enabled)
		clk_disable()

which is much easier.

Signed-off-by: default avatarUwe Kleine-König <u.kleine-koenig@pengutronix.de>
Tested-by: default avatarEmil Renner Berthing <emil.renner.berthing@canonical.com>
Signed-off-by: default avatarThierry Reding <thierry.reding@gmail.com>