Commit 09f1a8d8 authored by Dmitry Osipenko's avatar Dmitry Osipenko Committed by Greg Kroah-Hartman
Browse files

thermal/core/thermal_of: Stop zone device before unregistering it

[ Upstream commit 5e5c9f9a

 ]

Zone device is enabled after thermal_zone_of_sensor_register() completion,
but it's not disabled before senor is unregistered, leaving temperature
polling active. This results in accessing a disabled zone device and
produces a warning about this problem. Stop zone device before
unregistering it in order to fix this "use-after-free" problem.

Signed-off-by: default avatarDmitry Osipenko <digetx@gmail.com>
Signed-off-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210616190417.32214-3-digetx@gmail.com
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>
parent 505c12a1
0% or .