net: phy: micrel: ksz9131 led errata workaround
Micrel KSZ9131 PHY LED behavior is not correct when configured in Individual Mode, LED1 (Activity LED) is in the ON state when there is no-link. Workaround this by setting bit 9 of register 0x1e after verifying that the LED configuration is Individual Mode. This issue is described in KSZ9131RNX Silicon Errata DS80000693B [*] and according to that it will not be corrected in a future silicon revision. [*] https://ww1.microchip.com/downloads/en/DeviceDoc/KSZ9131RNX-Silicon-Errata-and-Data-Sheet-Clarification-80000863B.pdf Signed-off-by: Francesco Dolcini <francesco.dolcini@toradex.com> Reviewed-by: Philippe Schenker <philippe.schenker@toradex.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>