aspeed/watchdog: Correct timeout value
The driver was using milliseconds and programming it into a register which takes ticks of the watchdog clock, which runs at 1MHz. This meant we were off by 1000 with the desired value. When 06985289 ("watchdog: Implement generic watchdog_reset() version") was added the aspeed board would leave the watchdog running, causing it to bite before u-boot was done. Discovered by booting in qemu: $ qemu-system-arm -M ast2500-evb -drive file=test.img,format=raw,if=mtd -nographic -no-reboot -d cpu_reset U-Boot 2019.07-rc3-00091-g2253e40caef5 (Jun 06 2019 - 16:53:23 +0930) Model: Aspeed BMC DRAM: 496 MiB WDT: Started with servicing (60s timeout) MMC: In: serial@1e784000 Out: serial@1e784000 Err: serial@1e784000 Watchdog timer expired. Fixes: 06985289 ("watchdog: Implement generic watchdog_reset() version") Signed-off-by:Joel Stanley <joel@jms.id.au>